Heat Pumps

What Is Emergency Heat on a Heat Pump Thermostat?

Emergency heat is a manual setting that shuts off your heat pump and warms the house with backup heat alone. It is meant for a breakdown, not everyday use, and knowing how it differs from AUX heat can spare you an unexpectedly high electric bill.

By the HVAC-R Finest team. Updated November 18, 2026.

Technician testing an outdoor unit with a clamp meter

How a heat pump heats your home

A heat pump does not burn fuel to make heat. In winter it collects heat from the outdoor air and moves it indoors, and in summer it runs in reverse to cool the house. The U.S. Department of Energy calls heat pumps the most efficient form of electric heating, providing up to three times more heat than the energy they use.

Most heat pump systems also have a backup heat source. In many homes that is a set of electric heat strips in the indoor air handler. In a dual-fuel system, it is a gas furnace. That backup can run in two very different ways: auxiliary heat and emergency heat.

AUX heat vs EM heat at a glance

Both settings use the same backup heat source. The difference is who turns it on and whether the heat pump keeps running.

AUX heat is automatic

The thermostat turns on backup heat by itself when the heat pump needs help, such as on a very cold morning or after a big jump in the thermostat setting.

AUX heat works with the heat pump

The heat pump keeps running while the backup adds extra heat. Once the house catches up, the backup shuts off again.

EM heat is manual

You have to select emergency heat on the thermostat yourself. It stays on until you switch the thermostat back to regular Heat.

EM heat replaces the heat pump

Emergency heat shuts the heat pump off completely and heats the home with backup heat only, which is usually electric resistance heat strips.

When should you use emergency heat?

Use emergency heat only when the heat pump itself has a problem. Carrier says to switch to it only if the heat pump has broken down or malfunctioned, and Trane calls it a setting for a true emergency, such as an outdoor unit that has stopped running or is covered in heavy ice that will not clear.

Emergency heat is not a boost button. It does not make a working system heat better. It just turns off the most efficient part of it. If the heat pump is running, leave the thermostat on regular Heat and let it bring on AUX heat when needed. If you do switch to emergency heat, Trane advises calling for service right away.

Why emergency heat costs more to run

Electric heat strips work a lot like the coils in a toaster. They turn electricity directly into heat, one unit of heat for each unit of electricity. A heat pump moves heat instead of making it. Carrier puts it this way: electric auxiliary heat is 100 percent efficient, while a heat pump can be 300 percent efficient.

So when emergency heat runs for hours or days, your electricity use climbs. How much depends on your home, your system and the weather. The DOE also warns against manually setting back a heat pump thermostat if that makes backup electric resistance heat come on, because that heat is more expensive. With a gas furnace backup, the cost difference depends on local gas and electricity prices.

What it means if the AUX light stays on

Seeing AUX on the thermostat now and then is normal. It often shows up on cold mornings, after you raise the setting several degrees, and during a defrost cycle.

It is a different story when AUX stays on for long periods or comes on in mild weather. Trane says it is a concern if auxiliary heat comes on and stays on when it is above 40 degrees outside. Carrier lists possible causes such as a dirty air filter, a refrigerant leak, a faulty sensor or a thermostat raised too quickly.

Start with the easy checks. Replace a dirty filter and make sure nothing is blocking the outdoor unit. If AUX keeps running, have the heat pump checked by a technician.

Defrost cycle basics

In cold, damp weather, frost can build up on the outdoor coil. To clear it, the heat pump runs a defrost cycle. It briefly reverses, much like it does in cooling mode, to warm the outdoor coil and melt the ice.

During defrost, the outdoor fan may stop, you may hear a whoosh as the refrigerant changes direction, and you may see steam rising from the unit. That steam is melting frost, not smoke. The thermostat may show AUX while backup heat keeps indoor air from feeling cool. Trane says its defrost cycles usually last 3 to 5 minutes, and Bryant puts a typical cycle at about 5 to 15 minutes.

Call for service if the unit keeps switching into defrost, if the cycles keep getting longer, or if thick ice stays on the coil after defrost ends. Do not chip ice away with a hard tool, since the coil is easy to damage.

What to do if your heat pump quits on a cold Dallas night

Dallas winters are usually mild, but a hard freeze can catch a struggling heat pump. Run through these steps before you switch to emergency heat.

  • Make sure the thermostat is set to Heat and the fan to Auto.
  • Check that the thermostat has power or fresh batteries.
  • Replace the air filter if it is dirty.
  • Reset a tripped breaker once. If it trips again, leave it off.
  • Look for heavy ice or debris on the outdoor unit, but do not chip ice away.
  • If the outdoor unit still will not run, switch to EM heat and call for repair.
  • Remember that EM heat needs electricity, so it will not help in a power outage.

When to call for help

Call a technician if the heat pump is not running, if you have had to switch to emergency heat, if AUX stays on in mild weather, if ice will not clear, or if a breaker keeps tripping. Every day on backup heat costs more to run than a working heat pump.

HVAC-R Finest provides heat pump service and repair and heating repair for homes in Dallas, DeSoto and nearby cities. For repairs, you approve the quote before any work starts. If your heat goes out after hours, we offer 24/7 emergency HVAC repair. Call (972) 372-4458.

More HVAC Guides

Plain answers to common heating and cooling questions from the HVAC-R Finest team.

Frequently Asked Questions

Does emergency heat come on automatically?

No. Emergency heat is a manual setting you choose on the thermostat. Auxiliary heat is the backup that comes on automatically when the heat pump needs help.

Is auxiliary heat the same as emergency heat?

They use the same backup heat source, but AUX heat runs automatically alongside the heat pump. Emergency heat shuts the heat pump off and runs the backup alone.

Should I use emergency heat when it is below freezing?

Not just because it is cold. A working heat pump brings on AUX heat by itself when it needs help. Use emergency heat only if the heat pump has stopped working.

What if I accidentally turned on emergency heat?

Switch the thermostat back to regular Heat. Leaving EM heat on uses more electricity than letting the heat pump do the work.

Why is steam coming from my heat pump in winter?

It is usually a normal defrost cycle melting frost off the outdoor coil. If the unit stays covered in ice after defrost ends, call for heating repair.

Heat Pump Not Keeping Up?

Call (972) 372-4458 for heat pump and heating repair in Dallas and nearby cities, with 24/7 emergency HVAC service.